Precautions for operating the metal hose filling and sealing machine:
1. Clean up the debris in the hopper, add materials, and place the hopper filling cover in place;
2. Turn on the power of the metal hose filling and sealing machine, press the main power switch, and the counter will display 0; When the main power switch is pressed, the frequency converter displays "OFF". When the material reaches the desired temperature, press the "Run" button on the frequency converter, and the frequency converter will display "LS". At this time, turn the frequency converter knob clockwise (do not damage the internal tooth surface of the knob with too much force and slip it), the motor will start, the indexing plate will run, and the tail sealing mechanism will start running (the frequency converter knob can be adjusted to the appropriate operating speed at any time during operation);
3. Press the filling button of the metal hose filling and sealing machine (the photoelectric probe starts working) to start inserting the tube (the machine manually inserts the tube). When the turntable drives the empty tube to the filling nozzle, the photoelectric probe will receive a signal and start filling (filling the tube seat without the tube). When the metering pump completes an action, the micro switch receives a signal and the filling stops. The metering pump runs once and the counter counts once (the counter can be reset and counted again at any time); This cycle. (The new machine filling is to discharge the air from the metering pump, so it is empty filling);
4. Check the filling volume and adjust the measurement value if there is a difference.
5. After the metal hose filling and sealing machine is completed, turn off the filling switches one by one, turn the inverter knob counterclockwise until the indexing plate stops running, and cut off the power supply.
During the operation of the metal hose filling and sealing machine, do not touch the operating parts with your hands to avoid accidents. After adjusting the measurement value, be sure to tighten the nut. If any abnormal response occurs during the operation of the metal hose filling and tail sealing machine, the machine will not start until the cause is identified. When filling large capacity containers, the diameter of the filling nozzle should not be too small to prevent the rubber spray or nozzle from being damaged due to excessive pressure during the filling process.